NEU GRAND LIBRARY
Opening Hours: Monday-Saturday, 08:00-20:00 | E-mail: library@neu.edu.tr
 

You are not logged in Show Basket
  Home     Advanced Search     Back  
  Brief display     MARC Display     Reserve  
Effect Of Alloy Recasting On The Color Of Opaque Porcelain Applied On Different Dental Alloy Systems. (Yilmaz, Burak.)
Bibliographical information (record 267268)
Help
Effect Of Alloy Recasting On The Color Of Opaque Porcelain Applied On Different Dental Alloy Systems.
Author:
Yilmaz, Burak. Search Author in Amazon Books

Publisher:
Mosby-Elsevier,
Edition:
2012.
Classification:
WU 29
Detailed notes
    - Statement of problem. The effect of different proportions of recast dental alloys on the color of overlying opaque porcelain (OP) is unknown. Purpose. The purpose of this study was to compare the color of OP applied on 2 different proportions (50% and 100%) of recast alloys with the color of commercially available shade tabs of OP. Material and methods. Six different metal alloy systems (2 base: Metalloy CC, Cr-Co [B-MCC]; Heraenium NA, Ni-Cr [B-HNA]; 3 noble: Cerapall 2, Pd-Au [N-CP2]; Triumph, Pd-Ag [N-T]; V-Deltaloy, Au-Pd [N-VD]; and 1 high-noble: V-Gnathos Plus, Au-Pt [HN-GP]) were selected for the fabrication of disk-shaped specimens (10 mm in diameter, 1 mm in thickness). Each alloy was divided into 2 subgroups: 50% new alloy with 50% recast alloy (n=3) and 100% recast alloy (n=3). OP (B1) was applied (0.1 mm) to all specimens. The color coordinates (L*, a*, b*) of each specimen and the corresponding commercially available OP shade tab (control) were measured with a spectroradiometer, and color differences between specimens and control group were calculated. Data were statistically analyzed (2-way ANOVA, Ryan-Einot-Gabriel-Welsch multiple range test, alpha=.05). Results. For each alloy, Delta L*( Lcontrol-Lrecastalloy) values for the 2 subgroups were not statistically different from each other. The Delta a* and Delta b* of different proportions of N-CP2, B-HNA, N-VD, and HN-GP were not statistically different within the alloys. However, the a* values of 100% recast N-T and B-MCC were significantly closer to the a* values of the control group, and the b* values of 50% recast B-MCC were significantly closer to the b* values of the control group (P<. 05). Delta Econtrol-recast alloy values for different proportions of alloys were not statistically different. However, color differences did not meet the criterion of clinical acceptability (Delta E=3.46). Conclusions. According to the results of this study, the different proportions (50% and 100%) of recast alloys used have similar effects on the color of OP. Differences between the final color of OP on the recast alloys used and the color of OP shade guide tabs did not meet the criterion of clinical acceptability considered in this study. (J Prosthet Dent 2012;108:362-369)
Related links
Items (1)
Barcode
Status
Library
Section
EOL-1502
Item available
NEU Grand LibraryOnline (WU 29 .E34 2012)
Online electronic

NEAR EAST UNIVERSITY GRAND LIBRARY +90 (392) 223 64 64 Ext:5536. Near East Boulevard, Nicosia, TRNC
This software is developed by NEU Library and it is based on Koha OSS
conforms to MARC21 library data transfer rules.